Growers compare electricity costs per mole of supplemental light by dividing the price of one kilowatt-hour by the number of moles of photons a fixture delivers per kilowatt-hour. The result is a cost per mole in cents or euros. Because it combines fixture efficacy (µmol/J) with the local electricity tariff, it is a far more reliable yardstick than wattage or purchase price alone.
The calculation is simple, but the inputs need care: measured efficacy, real operating conditions, and the tariff structure you actually pay. The sections below cover the specs that matter, the formula, tariff effects, and the limits of the metric.
Which fixture specs determine electricity cost per mole?
Two specs determine electricity cost per mole: photosynthetic photon efficacy, expressed in µmol/J, and the electrical power the fixture draws at the wall. Efficacy tells you how many photons each joule of electricity produces. Higher efficacy means more light per kilowatt-hour and a lower cost per mole.
Look beyond the headline number on a datasheet. A few details change the real-world result:
- System efficacy versus component efficacy: Always compare efficacy measured at the fixture level, including driver losses, not LED chip efficacy.
- Test conditions: Efficacy varies with drive current and temperature. Check that figures come from an independent test report at the operating point you will actually use.
- PPF per watt: This is the same quantity as µmol/J. Total PPF (µmol/s) divided by input power (W) gives the efficacy figure you need.
- Dimming behavior: Many greenhouse LED lighting systems run below full output for much of the season. Efficacy at partial load can differ from efficacy at 100%.
- Spectrum: Red-heavy spectra are typically more efficient in raw µmol/J, but crop response may justify a broader spectrum.
How do you calculate cost per mole step by step?
To calculate cost per mole, convert efficacy into moles per kilowatt-hour, then divide your electricity price per kilowatt-hour by that number. A fixture with 3.0 µmol/J delivers 10.8 moles per kWh, so at €0.10 per kWh the cost is roughly €0.0093 per mole.
Follow these steps for any fixture:
- Find the efficacy in µmol/J. Use the measured system value, for example 3.0 µmol/J.
- Convert to moles per kWh. One kWh equals 3,600,000 joules. Multiply efficacy by 3,600,000 to get µmol per kWh, then divide by 1,000,000 to get mol per kWh. The shortcut: efficacy × 3.6. So 3.0 × 3.6 = 10.8 mol/kWh.
- Take your all-in electricity price per kWh. Include network fees and taxes if they apply to your consumption.
- Divide price by moles per kWh. At €0.10/kWh, that is €0.10 ÷ 10.8 = €0.0093 per mol, or about €9.30 per 1,000 mol.
- Compare across fixtures. Repeat with each candidate’s efficacy at the same tariff.
For a second example, a fixture rated at 2.6 µmol/J delivers 9.36 mol/kWh. At the same €0.10 price, the cost is about €0.0107 per mole, roughly 15% higher than the 3.0 µmol/J fixture.
How do electricity tariffs change the comparison?
Electricity tariffs change the comparison because the effective price per kilowatt-hour differs by hour, season, and region, so the same fixture can have a different cost per mole depending on when it runs. Time-of-use rates, peak demand charges, and grid fees all shift the result.
Growers in the Netherlands, Canada, the United States, and Scandinavia face very different tariff structures, and each deserves its own calculation:
- Time-of-use pricing: If lights run mainly during cheaper night or off-peak hours, use the average price over your actual lighting schedule, not the headline rate.
- Demand and capacity charges: In many North American markets, peak demand fees are a large share of the bill. A fixture that dims smoothly or allows staged switching can lower the demand component.
- Taxes and levies: Energy taxes and renewable surcharges vary widely between countries and can be partly reduced for horticulture. Use the net price you pay.
- Spot-market exposure: With dynamic contracts, cost per mole fluctuates hourly. Calculating it at several price points, such as low, average, and high, gives a realistic range.
A useful practice is to run the cost per mole calculation at two or three tariff scenarios for 2026. The fixture ranking rarely changes, but the absolute savings gap between fixtures grows as electricity gets more expensive.
Why can fixtures with equal efficacy cost differently?
Fixtures with equal efficacy can cost differently because efficacy alone ignores light distribution, heat output, dimming performance, and degradation over time. Two fixtures at 3.0 µmol/J may deliver very different usable light at crop level, and that changes the cost per mole that actually reaches the plant.
Several factors explain the gap:
- Light uniformity and optics: Photons that land between rows or on walkways are paid for but not used. Better distribution means more moles at canopy level per euro spent.
- Light maintenance: LEDs lose output over time. A fixture that holds its PPF longer keeps its cost per mole low across the years, while a faster-degrading one drifts upward.
- Heat contribution: In cold climates such as Canada and Scandinavia, heat from lamps offsets heating costs. In warmer periods, it can add cooling or ventilation load.
- Power factor and driver quality: Poor power factor can raise grid charges even when efficacy looks identical on paper.
- Crop fit: Tomato, cucumber, and lettuce respond differently to intensity and spectrum. Lettuce typically needs lower, more uniform intensity, while tomato and cucumber under-canopy or top lighting have different positioning needs.
Is the lowest cost per mole always the best choice?
No. The lowest cost per mole is a strong starting point, but the best choice balances it against investment cost, crop response, light distribution, and lifetime performance. A slightly more expensive mole that is better placed or better matched to the crop can deliver a higher return per square meter.
Use cost per mole alongside these criteria:
- Total cost of ownership: Combine purchase price, installation, energy over the fixture lifetime, and maintenance.
- Yield and quality response: The real target is revenue per square meter, not the cheapest light. Extra moles are only valuable if the crop can convert them.
- Control flexibility: Dimming and spectrum tuning allow you to lower the average cost per mole by adding light only when it is worth the electricity price.
- Reliability and support: Downtime during peak production costs more than small efficacy differences.
In practice, many growers set a maximum acceptable cost per mole for their tariff, then choose among qualifying fixtures based on crop fit and long-term performance.
How Dutch Lighting Innovations Helps with Comparing Cost per Mole
Comparing cost per mole only works when the inputs are accurate and tied to your crop, tariff, and greenhouse layout. Dutch Lighting Innovations supports growers with crop-specific lighting plans built on measurable energy performance rather than datasheet claims.
- Crop-specific configurations: Lighting designed around tomato, cucumber, or lettuce cultivation strategies, matched to your intensity and spectrum needs through our LED lighting products.
- Tariff-aware calculations: Cost per mole modeled against your actual electricity contract and lighting schedule, so you compare fixtures on real operating costs.
- Light distribution planning: Layouts that put more moles on the canopy and fewer on walkways.
- Season-long optimization: Ongoing involvement during the growing season to fine-tune dimming and light strategy for better energy efficiency.
- Proven results: See how this works in practice in Project Red Harvest.
Ready to see what your supplemental light really costs per mole? Contact our team for a tailored comparison based on your crop, location, and electricity tariff.